On a coastal lot, height is the scarcest thing you have. The flood zone rules push the lowest floor up. The height limit holds the roof down. Everything the house needs has to fit in between.
A ducted HVAC system spends that height on itself. Large ducts need a dropped ceiling or a deep floor cavity on every level. Lose that depth on each floor and the third level is the one that does not fit.
The Rye, NH house
This oceanfront house in Rye, New Hampshire had both problems. It is in a coastal flood zone and it is under a height limit. It has three full levels. It was able to have them because the heating and cooling are in a low profile ThermaCEILING and not in a large duct system.

ThermaCEILING is 1 7/16 in deep, measured with the ThermaTRAK and its clip. It fastens to the framing and the drywall goes over it. There is no soffit, no dropped ceiling and no duct chase.
The beams were the second problem
The house is framed with large laminated beams. Large ducts would have been impossible to route past them.
ThermaCEILING did not have that problem. The panels sit in the plane of the ceiling, between the beams, and the fluid reaches them through small pipe.

The only other option
Without large ducts, the only other way to cool this house was mini splits, paired with radiant floors for heat. Mini splits are noisy and unattractive. Radiant floors are inefficient and cannot cool effectively. That is two systems, with equipment on the walls of every room.
What the ceiling does
The same ceiling heats and cools every room, in silence, with no vents or grilles. Fluid across the whole surface lets mild fluid temperatures do the work. High output at low temperatures means high COP for heat pumps.

Fresh air still needs ducts, but small ones
The ceiling handles the sensible load, which is temperature. Fresh air and humidity are handled by a separate system that Design Day Mechanicals designed for this house: a standard ERV, a dehumidifier and a steam humidifier, with a cooling coil on the dehumidifier outflow so the air returns at room temperature, at a flow rate you cannot detect. Its ducts are small and well placed, because they carry only fresh, humidity controlled air. Small ducts fit where large ones cannot. Read how the fresh air system is decoupled from the ceiling.
Where this matters
- Flood zones. The lowest floor is raised, so every inch above it counts.
- Height restricted lots. The roof is capped, so floor to floor height decides how many levels fit.
- Heavy structure. Large beams leave no path for large ducts.
- Commercial floors. In a commercial building ThermaCEILING can save 20 percent of the building volume by replacing the large HVAC ducts and plenums that require a taller floor to floor height on every level.
Send us your plans
If the height limit and the program do not agree, send us the plans before the floor to floor heights are fixed. We will show you what the ceiling depth can give back. Plan and product review, or call (603) 319-8815.