Snowmelt in New York City

New York is where ThermaPANEL works highest: under 4 inch granite on The Edge NYC at Hudson Yards, 1,100 feet above the street, and on rooftop terraces from Midtown to Brooklyn. In this city the snowmelt question is the heat source. Local Law 154 keeps gas out of new buildings and Local Law 97 counts every unit of fuel. A panel that melts at heat pump temperatures, with no slab to heat first, is what those rules ask for.

Robert Barmore, founder

The Edge NYC at 30 Hudson Yards, the observation deck cantilevered 1,100 feet above Manhattan, granite on ThermaPANEL
The Edge NYC, Hudson Yards. The deck that hangs off the tower, 1,100 feet up, is 4 inch granite on ThermaPANEL.

Our work in New York

  • The Edge NYC, Hudson Yards. The observation deck, 4 inch granite slabs on ThermaPANEL, 1,100 feet above the street.
  • SUMMIT One Vanderbilt. Granite pavers on pedestals over ThermaPANEL.
  • Aman New York, Crown Building. Terraces on pedestals over ThermaPANEL.
  • The Edition, Times Square. The rooftop terraces on pedestals over ThermaPANEL.
  • QC NY, Governors Island. The paver decks around the year round spa pools, and the walks between the barracks.
  • Delta Terminal C, LaGuardia Airport. The pedestal paver walkways that lead crews across the Concourse F roof to the equipment, plus ThermaPANEL for Delta’s Sky Way program at LaGuardia.
  • The Redbury, NoMad. The hotel terrace.
  • The Williamsburg Hotel, Brooklyn. The rooftop water tower bar, with ThermaPANEL under the wood floor.
  • RH Guesthouse, Meatpacking District. The rooftop pool deck: ThermaPANEL mounted on grating, with pavers on top.
  • Private terraces and penthouses across Manhattan and Brooklyn. We never publish owner names or addresses.
Finished granite observation deck at The Edge NYC, Hudson Yards, glass walls over the Hudson River
The finished deck at The Edge. ThermaPANEL is under every slab of granite, out of sight, with the Hudson River 1,100 feet below.
Aman New York garden terrace on the Crown Building, Fifth Avenue, pavers on pedestals over ThermaPANEL
Aman New York, Crown Building. The garden terrace pavers sit on pedestals over ThermaPANEL.

What we melt here

  • Roof terraces and setbacks on pedestals. The panel sits directly under the pavers with its insulation built in. No topping slab, no mortar bed. The added weight is the panel, one quart of fluid per panel, and the pavers you were installing anyway, which matters on an existing roof. Only the supply and return mains penetrate the roof.
  • Heavy stone. ThermaPANEL carries 4 inch granite on The Edge NYC. Where stone is too thin or too small to be carried at its corners, grating on pedestals goes under the panels to give it full support.
  • Egress paths and walks. Exits, stairs and walks that have to stay open in a storm.
  • Pool decks. The same panels keep a pool surround clear, and can heat the pool from the sun in summer.

New York’s rules

Local Law 154 bars on site combustion of fuels above 25 kg CO2 per MMBtu in new buildings: under seven stories for permits filed from January 1, 2024, and all buildings from July 2, 2027. Snowmelt is not among the exemptions, so a gas snowmelt boiler is out in a covered new building. Local Law 97 caps whole building emissions for buildings over 25,000 square feet, with a $268 per metric ton penalty and limits that roughly halve in 2030, and snowmelt fuel counts against the cap. The 2025 NYC Energy Conservation Code carries the snowmelt control rule at C403.14.2. Heated public sidewalks need a DOT revocable consent.

What that means for design: the heat source is a heat pump, and the surface has to melt at the temperature a heat pump makes. ThermaPANEL is designed for 100 to 130 F supply. Confirm the current rules with the Department of Buildings before you submit. More on tall buildings is on our high rise page, and the rules for other cities are on our snowmelt energy codes page.

QC NY spa pool deck on Governors Island, pavers over ThermaPANEL, with the Lower Manhattan skyline across the harbor
QC NY on Governors Island. The pool deck pavers run on ThermaPANEL, with Lower Manhattan across the harbor.
The Williamsburg Hotel water tower bar in Brooklyn, with its wood floor heated by ThermaPANEL and the Manhattan skyline through the windows
The Williamsburg Hotel, Brooklyn. Inside the rooftop water tower bar, the wood floor sits on ThermaPANEL.

Built for the city

  • Low temperature fluid. We design around 100 to 130 F supply, with 140 F as the ceiling. That is the range air to water heat pumps are built to deliver.
  • Glycol mixed for the site. The fluid is propylene glycol mixed with deionized or demineralized water, and the mix is set by the project address, not a one size default.
  • Light on the structure. One quart of fluid per panel and no slab. On an existing roof that can be the difference between a terrace and none.
  • UV protection in the paver joints. Sunlight reaches the system through the gaps between pavers. PEX tubing exposed to UV voids its warranty. ThermaPANEL and our tubing are made from PE-RT filled with carbon black, which protects them from UV.
  • Repairable. If a panel is ever damaged, lift the pavers and swap it. Tubing in a slab on a roof means tearing out the slab.

How a project starts

Call us, or book a Zoom plan and product review where we go over your drawings live. Then we send a sample kit that fits your application. To start a project, send us:

  1. Plans with a defined perimeter for each area to be melted.
  2. Cross sections through the assembly.
  3. Your preferred paver type and layout.
  4. The heat source, usually an air to water heat pump in New York.

Residential: full plan sets are welcome, so we understand the entire project.

Commercial: provide the areas to be treated and the sections, with a note showing the location of the mechanical room.

We return a panel layout, a BTU estimate, and a mechanical schematic. Therma-HEXX supplies the complete mechanical package, not just panels, and supports your contractor through the install. Contact Therma-HEXX engineering or call (603) 319-8815.

Questions from New York projects

Can a new building in New York use a gas boiler for snowmelt?

Not in a building covered by Local Law 154. Snowmelt is not among its exemptions, so the heat source in a covered new building is electric, which in practice means a heat pump.

Does snowmelt count against Local Law 97?

Yes. Snowmelt fuel counts against a building’s emissions cap, which is why melting at heat pump temperatures with no slab to heat first matters.

Can a roof terrace have snowmelt without a topping slab?

Yes. On a pedestal terrace the panels sit between the pedestal heads and the pavers. There is no slab, and only the supply and return mains penetrate the roof.

Related: snowmelt by region · high rise terraces · pedestal paver snow melting · snowmelt energy codes by town